• Front view
  • Back view
The AM-S208E controller has self-developed video playback software, light point wiring design software, and sufficient interfaces to facilitate compatibility with other communication protocols. It adopts Ethernet interface and UDP network protocol for stable transmission, and the maximum transmission distance is 100 meters; supports win7, win8, win10 operating systems; meets customer's personalized customization needs; AM-S208E controller compulsory Gigabit, supports multiple controllers cascading, The total number of load points can reach millions of points, which can meet various engineering applications.

Function

  • Controller output supports standard USITT DMX512/1990 general protocol and extended DMX protocol;
  • Independent brightness control of the three primary colors makes it easier and more effective to accurately adjust the white balance;
  • Precise gamma correction algorithm, which is more in line with the human visual sensitivity characteristics, and the display color is rich;
  • The maximum support for the frame change frequency of 120 to ensure the screen high-definition display and 3D display requirements;
  • Using Ethernet interface and UDP network protocol for stable transmission, with a maximum transmission distance of 100 meters;
  • LCD display module displays controller parameters and status in time;
  • Dual network interfaces, cascading between controllers can be realized; the controllers are automatically detected, and the software is visually displayed;
  • 8-port output, single-port output standard 512 channels, support extended protocol, load points are tested by customers according to chip characteristics;
  • Gigabit high-speed Ethernet, easily realize the control of megapixel lamps;
  • Support online code writing and parameter setting of DMX512 driver IC such as Lianxinke and Mingwei;
  • Support the arbitrary adjustment of the brightness of each channel, low-gloss filtering and other functions;
  • Support optical fiber transmission after optical fiber module conversion;
  • Cooperate with Internet control software to realize Internet remote control;
  • The system supports automatic, timing, and holiday preset effects playback;
  • Synchronous and asynchronous integrated control: online priority, no online signal automatically switches offline effects;
  • Various debugging tools to facilitate the debugging of the lamps and lanterns on the project site and improve the production efficiency;
  • Real-time detection of the operating status of the controller, visual display of the computer software and alarm function;
  • Hardware real-time detection, support arbitrary shielding of the controller and any port of the controller;
  • The controller is forced to gigabit and supports cascading of multiple controllers. The total number of load points can reach millions of points, which can meet various engineering applications.

Parameter

  • Model Name:AM-S208E controller
  • Control color:RGB three primary colors, full color display
  • Control points:8-channel DMX512 (support standard DMX512 and extended DMX512)
  • Gray level:256~65536
  • Output Interface:8 DMX512 differential/TLL signal output
  • Input voltage:AC100~240V
  • rated power:MAX15W
  • Ambient temperature:-40~80°C
  • Unit size:292*150*50mm
  • Supporting software:EconPlayer

Design concept

  • 1、Support four-color and five-color; various color algorithms to make the colors richer and purer;
  • 2、Support IP grouping function, use switch parallel scheme: reduce the system cascade chain length to improve stability, support ID lock;
  • 3、Independently develop video playback software and light point wiring design software, leaving sufficient interfaces to facilitate compatibility with other communication protocols;
  • 4、Support win7, win8, win10 operating system; meet customer's personalized customization needs.

Support individual needs

  • Can install all current Windows operating systems and support various languages;
  • The playback software has sufficient interfaces in order to be compatible with other international common protocols and support customers' individual design requirements.

Equipment cascading

Output port definition

The controller uses 8 5pin terminal interfaces to output signals. 5pin terminal signals are sorted from left to right:

The controller network interface adopts Gigabit Ethernet for data transmission, and the graded network cable used must meet the requirements of Gigabit network transmission conditions. It is recommended to use Category 6 pure copper network cable. The network cable that meets the CAT6 standard shown in the figure below can provide twice as much as Category 5 network cable, and has smaller crosstalk, much better return loss, and higher transmission performance stability. .

Correct connection of crystal head

lt is better to use a crossover cable between the controller, the offline main control and the switch,which is 568B at one end and 568A at the other end The network cable between any of the abovedevices and the computer uses a straight-through cable, that is, the two ends are both 568B or 568ADo not define the straight-through cable sequence yourself.

Wire and connection method from lamp to controller

  • 1、if the distance between the output port of the controller and the lamp is too far,it is recommended to use a 485dedicated line or a shielded network cable above Category 5 to connect The best connection method is:Orange-A; orange-white-B; others connected to GND(ground).
  • 2、A 12OR terminal resistance should be added to the end of each signal,between A and B.
  • 3、Do not use the two wires that are twisted together to connect signals at the same time. For example, orange andorange and white are connected to A+ or B-at the same time.
  • 4、The controller is a non-waterproof device, and it needs to be equipped with a waterproof box as standard foroutdoor installation, and the ground wire must be effectively grounded.
  • 5、The connection of all lamp end joints must be hot-tin welded and then covered with heat-shrinkable sleeves, andthen the joints should be insulated and waterproofed.
  • 6、To install the controller,you need to connect the wires and tighten the terminal screws to ensure that it is stable andprevents falling.
AMUCHIP MICRO ELEC-TECH(ZHONGSHAN) co., LTD